Dear ISIS experts, I have realised that the chi2 value for rebinned spectra is very different when calculated by ISIS and XSPEC. The chi2 is exactly the same when I use non-binned spectra, so the difference must arise with the way of calculating errors after rebinning. I am using the default fitting method (which seems to be the same for XSPEC and ISIS) and rebin the HEG spectra to have a minimum of 25 cts/bin. Before rebinning, a simple power law fit gives me a chi2 of 838.37 for 2362 dof both in ISIS and XSPEC. After rebinning, I get: XSPEC: Chi2 of 217.90 (460) ISIS: Chi2 of 420.46 (460) So the difference is almost a factor of two, and the parameters of the fit are also different. Do you know why am I getting such a difference? Best, Maria ---- You received this message because you are subscribed to the isis-users list. To unsubscribe, send a message to isis-users-request_at_email.domain.hiddenwith the first line of the message as: unsubscribeReceived on Tue Apr 29 2014 - 05:44:58 EDT
This archive was generated by hypermail 2.3.0 : Fri May 02 2014 - 08:35:48 EDT