On Mon, Feb 03, 2014 at 05:48 -0800, juan luna wrote: > > I know that XSPEC now has included an option to use APEC > emissivities instead of mekal in the mkcflow model (switch=2). > In the ISIS version, the switch parameter can take values of 0 > or 1, but it works if I set the value to 2. My question is if > the model is using APEC emissivities when I set switch=2 in > ISIS?. > When isis executes the mkcflow model, it's using exactly the same code and reference data as the corresponding xspec installation would use. Isis doesn't change the meaning of the parameters of any of the xspec models. As long as the the APEC emissivities are found where the model expects them (meaning that all necessary environment variables have been set, necessary data files installed, etc.), then the switch should have the effect described in the xspec documentation. Thanks, -John ---- You received this message because you are subscribed to the isis-users list. To unsubscribe, send a message to isis-users-request_at_email.domain.hiddenwith the first line of the message as: unsubscribeReceived on Mon Feb 03 2014 - 09:36:55 EST