juan> I'm using the mkcflow model to fit my data, the maximum juan> temperature is 20 keV. I wonder why the fitted lines looks juan> with flat top (see attached figure). The same happens in all juan> the lines. Hi Juan, Set the switch to 0: > set_par("mkcflow(1).switch", 0); This will force the model to be calculated, rather than interpolated. I suspect that the tabulated models have a very coarse energy grid, a relic of the pre-grating days of X-ray astronomy. -- Dave David Huenemoerder 617-253-4283 (o); -253-8084 (f); http://space.mit.edu/home/dph MIT Kavli Institute for Astrophysics and Space Research 70 Vassar St., NE80-6065, Cambridge, MA 02139 [Admin. Asst.: Elaine Tirrell, 617-253-7480, egt_at_email.domain.hidden ---- You received this message because you are subscribed to the isis-users list. To unsubscribe, send a message to isis-users-request_at_email.domain.hiddenwith the first line of the message as: unsubscribeReceived on Wed Jul 30 2008 - 18:13:40 EDT
This archive was generated by hypermail 2.2.0 : Wed Jul 30 2008 - 21:38:01 EDT